GR 2000
|
The model of the GR 2000 incorporates a digital display meter multiple seven key parameters for monitoring generator sets.
- Voltage (VAC): three stages; Current (ACA): three stages; Frequency (Hz).
- The GR 2000 may be calibrated for measurement of AC according to the ratio of current transformer and potential.
|
|
Shark 100
|
The digital multimeter of eectrical quantities, EIG / ENGRO, SHARK100/200 model for use in electrical panels. Front mounting, with dimensions that meet the drilling of DIN and ANSI.
With simultaneous indication of threes quantities, three displays LED's high gloss front, the device displays:
- Voltage phase-phase and phase-neutral;
- Total harmonic distortion (up to 40 th) has two ports, one front that lets you communicate by infra-red and the other on the back of the instrument (RS485) with MODBUS RTU, ASC-II or dnp-3.0.
|
|
Shark 200
|
Digital multimeter Electrical Quantities, EIG / ENGRO, SHARK100/200 model for use in electrical panels. Front mounting, with dimensions that meet the drilling of DIN and ANSI.
With simultaneous indication of three quantities, three displays LED's high gloss front, the device displays:
- Voltage phase-phase and phase-neutral;
- Total harmonic distortion (up to 40 th) has two ports, one front that lets you communicate by infra-red and the other on the back
the instrument (RS485) with MODBUS RTU, ASC-II or dnp-3.0. |
|
Nexus 1250
|
The "Electronic Meters" NEXUS 1250 are produced for testing, monitoring and billing of energy "expanding" the concept of measurement.
Functional Features:
- Measurement of three-phase bidirectional active energy;
- Measuring bidirectional three-phase reactive power (four quadrants);
- Measurement of the indicators of quality of energy;
- Voltage and RMS Voltage Variation in Short Term;
- Provides the primary quantities of voltage, current, power factor per phase;
- Mulltitarifa Recorder (Time Of Use TOU);
- Schedule of daylight saving;
- Program parameters for calculation of transformer loss compensation processing;
- High compression module with electronic components surface mount (SMD) ensures high immunity to noise;
- Recording waveform up to 255 th order;
- Measurement of SAG, Swell w / Nexus 1250;
- Mode of diagnosis with monitoring of all voltages, currents, power factors, spectrum of harmonics up to 63rd order, kW, kVA, frequency and phasor diagrams;
- Clock high precision better than one second per month;
- Schedule / read local and remote via software installed on PC / notebook;
- Analysis by Nexus Communicator 2.0 software.
|
|
Nexus 1252
|
The "Electronic Meters" NEXUS 1252 are produced for testing, monitoring and billing of energy "expanding" the concept of measurement.
Functional Features:
- Measurement of three-phase bidirectional active energy;
- Measuring bidirectional three-phase reactive power (four quadrants);
- Measurement of the indicators of quality of energy;
- Voltage and RMS Voltage Variation in Short Term;
- Provides the primary quantities of voltage, current, power factor per phase;
- Mulltitarifa Recorder (Time Of Use TOU);
- Schedule of daylight saving;
- Program parameters for calculation of transformer loss compensation processing;
- High compression module with electronic components surface mount (SMD) ensures high immunity to noise;
- Recording waveform up to 255 th order;
- Includes the role of Flicker;
- Mode of diagnosis with monitoring of all voltages, currents, power factors, spectrum of harmonics up to 63rd order, kW, kVA, frequency and phasor diagrams;
- Watch the high precision better than 1 second / month;
- Schedule / read local and remote via software installed on PC / notebook;
- Analysis by Nexus Communicator 2.0 software.
|
|
Nexus 1500
|
The solution to power quality, oscillography and measurement of all relevant electrical parameters such as SAG / SURGE, SWEL, Flicker, Display with 256 colors.
- Measurement at 512 samples per cycle or 1024 (optional)
- Capture transient 10Mhz 166 000 samples per cycle;
- Memorial mass 128 Mbyte 1 Giga (optional)
- Curve CBEMA Log, Analysis Fazonial;
- Harmonic Distortion until order 512Th;
- Records Multitarifa schedule (TOU) up to 20 years;
- A 100 base T Ethernet port RJ-45, optional second, 8 simultaneous connections;
- Communication protocols Modbus TCP, DNP-3.0.
|